Send Maidong your stainless steel crimped woven screen panel requirement for quotation review. Define the opening, wire size and crimped structure together with the finished panel outline and fixing arrangement.
For equipment replacements, attach the panel drawing and identify the support and edge interfaces that control installation.

Specify the Construction Before Selecting a Panel Size
Describe the required crimp and weave arrangement using an approved reference or sample information. Give the wire diameter and clear opening in both directions where needed, rather than using one mesh number as a complete description.
Identify the stainless designation and any material records required. Keep the proposed construction explicit if the original specification is incomplete. A visually similar panel should not be accepted as equivalent without reviewing the relevant requirements.
For welded intersections, see stainless welded wire mesh panels. This page concerns woven construction.
Define the Supplied Edge Arrangement
Bare panel
Specify the cut outline, edge reference and permitted wire projections.
Retained or framed panel
Give the frame or edge-strip material, clear opening and assembly envelope.
Equipment-specific edges
Show any hooks or formed fixing features, including orientation and reference dimensions. Feasibility requires review.
Do not assume that a general panel quotation includes mounting hardware or an equipment-specific tensioning arrangement. List each required part and operation on the drawing.
Panel Quotation Checklist
| Material | Stainless designation and requested material documentation. |
|---|---|
| Wire and openings | Wire diameters, clear openings, units and applicable tolerances. |
| Crimp construction | Weave/crimp reference and directional arrangement. |
| Finished dimensions | Panel length and width, outline, measurement reference and drawing revision. |
| Edges | Wire projections, retained margins, hooks or other defined fixing features. |
| Equipment interface | Support positions, clamping areas, installation direction and mating dimensions. |
| Service | Intended screening duty, material handled and relevant operating conditions. |
| Inspection and delivery | Acceptance checks, quantity, identification, handling and packing requirements. |
Use a numbered list for multiple openings or panel sizes. Separate the outside dimensions from the clear working area and any fixing allowance already included in the drawing.
Confirm Installation and Acceptance Conditions
Show how the panel is supported and retained in service. The frame opening, clamp position and panel edges must be assessed together. A matching nominal width alone does not establish an interchangeable replacement.
State the condition in which dimensions and flatness are assessed. If a curved or tensioned installed form is required, supply the equipment requirements and identify how the delivery form relates to them.
Describe the material being screened and the desired separation result. Opening geometry alone does not establish throughput, wear life or equipment capacity. Any required evaluation must use agreed operating conditions.

Prepare a Replacement or New-Panel Enquiry
For a replacement, provide the approved drawing or record the available sample measurements. Identify damaged or uncertain features rather than treating them as the intended specification.
Where the proposed material or construction differs, use mesh replacement comparison guidance to record the differences. Confirm accepted changes against the relevant item and revision.
Agree packing that protects the panel edges and prevents the parts from becoming mixed. Availability, processing scope, minimum quantity, price and delivery are reviewed against the complete specification.
English Enquiry Template
Please review stainless steel crimped woven screen panels to drawing [number/revision].
Grade and crimp/weave reference: [details]. Wire diameter and clear openings: [values and units]. Finished dimensions and quantity per size: [list].
Edges, fixing features and installation direction: [drawing]. Support and operating conditions: [details].
Inspection, identification and packing: [requirements]. Please confirm the included scope and identify any proposed deviations.
Crimped Woven Screen FAQ
It is a panel of interlaced wires with a specified crimped construction. Identify the required wire arrangement and opening rather than relying on a general mesh description.
No. Woven and welded intersections are different constructions. Specify the required structure and obtain approval before substituting one for the other.
Give the clear opening dimensions and wire diameter in each direction where relevant. State the weave or crimp reference and units.
Only when separately specified and confirmed. A bare panel does not automatically include formed hooks, edge strips, a frame or tensioning hardware.
No. Include the finished dimensions, support and fixing interfaces, edge arrangement and equipment drawing. Width alone cannot establish compatibility.
No. State the required designation and requested documentation. Photos help explain geometry, but cannot certify alloy or exact dimensions.
Request a Crimped Screen Panel Quotation
Send the wire construction, panel drawing and quantity. Include the equipment interface where installation controls the part.
Purchasing Specification Review
Specify stainless steel crimped woven screen panels by the cloth construction and the equipment interface together. State the clear openings, wire size, crimp profile, finished panel dimensions and fixing arrangement. For replacement screens, identify what is confirmed by the machine drawing and what is only measured from a worn sample.
Match the panel to the installation
Working direction and support contact
Mark the material travel direction, working face and screen orientation where these affect the construction. Show support positions and the panel area retained by the machine. A panel with the same overall dimensions can still seat differently if its wire profile, thickness or edge arrangement changes.
Outline is not a fixing specification
Identify whether the supply is a bare panel, a retained panel or an assembly with formed fixing features. Give reference dimensions for hooks, edge strips or other attachments where required. Do not assume that generic woven-panel supply includes a compatible machine tensioning system.
Evaluate a replacement without assuming equivalence
Record the screening duty
Describe the feed material, wet or dry process, particle range, loading and operating motion. Include observed wear or blinding where relevant. A proposed aperture or crimp change should be reviewed against the process and supports, not accepted solely because it can be cut to the same outline.
Keep construction-specific acceptance
Name double crimp, lock crimp, intermediate crimp or flat top only when that profile is required and identified. Keep dimensional inspection, material evidence and any process trial as separate acceptance questions. The panel description does not establish an equipment capacity or structural safety rating.
Additional Buyer Questions
Is a crimped woven panel equivalent to welded mesh?
No. The intersections are retained by a different construction. Review any substitution against the application and installation.
Can a worn screen define the original opening?
It provides a current observation, which may include wear or distortion. Confirm the intended specification using design records where available.
Does flat top identify which face is installed upward?
The required working face and installation direction should still be marked on the specification or drawing.
For the wider product range, see Crimped Wire Mesh.
Related specification resources: Stainless Steel Lock Crimp Wire Mesh; Stainless Steel Intermediate Crimp Wire Mesh; Stainless Steel Double Crimped Wire Mesh; Hooked Screen Drawings and Tension Direction: RFQ Guide.
Specification Handoff and Enquiry Example
| Quotation review | Information to provide |
|---|---|
| Cloth | Opening, wire diameter, crimp pattern and material |
| Panel | Finished outline, edge form and orientation datum |
| Mounting | Equipment reference, support contact and fixing details |
Example RFQ Line to Complete
Replace the bracketed fields with your order requirements:
Crimped panel; equipment [reference]; material [grade]; opening [value/unit]; wire [diameter/unit]; crimp [type]; finished size [drawing]; supplied edge [detail]; working direction [datum]; quantity [value].